Digitermo Heat Meter Technical Information: Installation Conditions, Battery and Communication

Installation conditions, battery types and battery life, and the optical and M-Bus communication interfaces of Digitermo ultrasonic heat meters.

General information and installation conditions

Please read the user manual before installing the heat meter. If installation does not comply with the conditions in the manual, the Digitermo warranty becomes void. The following conditions must be met during installation:

  • Maximum pressure: PN16 / PS16
  • Environmental class: E1, M1, A
  • Installation point: at least 25 cm away from signal cables.

If the system water temperature is below 10 °C or above 90 °C, wall mounting of the calculator is recommended. Unions must be used for meter installation; installation using liquid sealants is not appropriate.

Note: if the seal or other security marks are tampered with or damaged, the product is no longer covered by the warranty and its calibration is considered invalid.

Power supply (battery)

The 18505 or 26500 batteries used in Digitermo meters provide a battery life of 5 or 10 years respectively.

PropertyValue
Battery typeLithium thionyl chloride
Model1 × 18505 / 1 × 26500
Capacity4000 mAh / 8500 mAh
Voltage3.6 V
Maximum dimensions18.0 × 50.5 mm / 26.2 × 50.0 mm
Operating temperature−55 °C … +85 °C

Communication interfaces

Optical interface

Digitermo is manufactured with an optical interface compliant with IEC 62056-21, enabling communication and service operations via the optical port.

  • Hardware interface standard: IEC 62056-21
  • Communication protocol: EN 13757-3
  • Baud rate: 2400 baud, parity: even, stop bits: 1

M-Bus interface

  • Interface: 2 wires, polarity-independent
  • Voltage: max. 50 V
  • Protocol: EN 13757-3
  • Baud rate: 2400 baud, parity: even, stop bits: 1
  • Addressing: primary and secondary addressing available as standard.

Versions with M-Bus or pulse output are supplied with 2 cables with metal ends for connection.

Shipping and storage

Heat meters are sensitive devices and must be protected against impact and vibration. Store the meters in a frost-free place (also during transport), as frost can damage them. Never carry the meter by the calculator — hold it only by the flow pipe. Watch out for sharp edges.